AI reconstructs high-resolution fluorescence lifetime images from faster, lower-resolution scans

By: ucla ita
 
LOS ANGELES - Aug. 16, 2026 - PRLog -- Fluorescence lifetime imaging, or FLIM, lets researchers see biochemical detail in tissue without dyes or stains, by tracking how long molecules glow after being hit with a pulse of light. That glow duration carries information about metabolism and tissue health that standard microscopy cannot capture, which is why FLIM has attracted interest for applications such as cancer diagnostics and surgical guidance. However, collecting enough light to accurately measure lifetime at every point in an image means scanning slowly, especially across large tissue areas.

A team at UCLA set out to work around that limit. Led by Professor Aydogan Ozcan and in collaboration with Professor Laura Marcu's group at UC Davis, the researchers built a deep learning system called FLIMPSR that reconstructs higher-resolution FLIM images from scans captured at much lower resolution. Paloma Casteleiro Costa, a postdoctoral scholar, is the first author of the study, now published in PhotoniX journal.

FLIMPSR is a generative adversarial network (GAN) trained to reconstruct spatial features lost when FLIM data is collected quickly. The team showed the model could recover accurate images from scans taken with pixels five times larger than usual, a 25-fold jump in effective resolution, without any change to the imaging hardware itself. They also tested a diffusion model, a newer and more computationally intensive class of generative AI, on the same task, and found their approach produced cleaner results in a fraction of the processing time, while being less likely to introduce artifacts that did not reflect the real tissue, a concern for any tool that might eventually inform a medical decision.

To test the system, the researchers scanned head and neck tumor tissue from patients and set aside three patients' worth of high-resolution scans that the model never saw during training. Applied to that held-out data, FLIMPSR reconstructed images that closely tracked the original high-resolution scans, preserving fine tissue structure that would normally be lost at faster scan speeds. Reconstruction quality held up across a fivefold resolution gap; pushing much further, both the GAN and the diffusion model began to break down.

The researchers also demonstrated that a short round of additional training can make the model hold up under noisier scanning conditions, the kind that might come from lower-cost equipment or more aggressive scan speeds, without hurting its performance on cleaner data.

Next, the research group plans to explore whether the same approach extends to wide-field FLIM systems, which face a different version of the same resolution-speed trade-off. If the method holds up under those conditions, it could help move high-resolution FLIM out of the research lab and into faster-paced clinical settings, including surgery, where images need to be processed in real time.

Article: https://link.springer.com/article/10.1186/s43074-026-00277-9
End
Source:ucla ita
Email:***@ucla.edu
Tags:AI image reconstruction
Industry:Science
Location:Los Angeles - California - United States
Subject:Reports
Account Email Address Verified     Account Phone Number Verified     Disclaimer     Report Abuse
UCLA Engineering Institute for Technology Advancement News
Trending
Most Viewed
Daily News



Like PRLog?
9K2K1K
Click to Share