HVI-TEC 20kV LIU Universal broadband isolation transformer

HVI-TEC 20kV LIU Universal broadband protection transformer for wired transmission technology, recommended for VDSL2 and G.fast between 200Hz and 30MHz up to 280Mbit/s.
By: HVI-TEC Luescher, formerly know as Telbit AG
 
ZURICH - June 7, 2022 - PRLog -- The latest revolutionary passive protecting devise for the Telecommunication Industry, will be made available worldwide, after it has been very successful within the Swiss market for more than one year. The technical specifications have not been matched by any passive protecting device on the market so fare.

Copper wire communication cables serving power plants and substations can be exposed to thousands of volts during a power system fault. Fault currents, returning to their source via the power station ground mat produce dangerous and destructive Ground Potential Rise (GPR), Earth Potential Rise (EPR), longitudinally induced voltages and noise in telecommunication cable facilities.

Protecting Broadband Transformers are required to protect Personnel and Telecommunication Equipment located within the Zone of Influence (ZOI) and provide reliable Digital Telecommunication and High Speed Data Transfer in high voltage environments like power plants and substations, while enabling maximum bandwidth. The passive design favors its reliability and reduces the failure rate to zero.

As wireless communication continues its exponential growth the need for wireless antenna sites also increases. Many of these wireless towers are installed at high voltage corridors, making these critical circuits susceptible to power faults and ground potential rise (GPR). These circuits need isolation from these potentially devastating faults, and the isolation must allow the circuit to remain in service during the fault condition.

The enormous bandwidth enables to use the existing telecommunication lines entering high voltage environments while upgrading your power plant or substation automation system and communicate with up to VDSL2 and VoIP. The HVI-TEC 20kV / 1:1 Protecting Transformer has been tested from 150Hz up to fare more than 50MHz (which exceeds the frequency range of today's data transfer about 10 times) and a data transfer rate of up to 300Mbit/s.

An extremely small footprint makes it ideal for installations where space is at a premium. In addition, the HVI-TEC 20kV Broadband Isolation Transformer will reduce next-talk effects, due to insufficient connection symmetry and enables the symmetric connection of communication equipment with asymmetric input, or communication Equipment with insufficient connection symmetry. Signal Protecting Transformers are passive Telecommunication Components, which cannot be replaced by Electronic Components, because of their unique application. Signal Protecting Transformers provide a Galvanic separation of power circuits, for example separation of incoming (P=primary) and outgoing (S=secondary) line as a potential separation (20kV protection) to protect connected communication equipment, from dangerous high voltage peaks, like lighting, GPR / EPR or induction.

For inquiries please contact us at info@hvi-tec.ch
End
Source:HVI-TEC Luescher, formerly know as Telbit AG
Email:***@hvi-tec.ch Email Verified
Tags:GPR
Industry:Telecom
Location:Zurich - Zurich - Switzerland
Subject:Products
Account Email Address Verified     Account Phone Number Verified     Disclaimer     Report Abuse
HVI-TEC Luescher - Telbit AG News
Trending
Most Viewed
Daily News



Like PRLog?
9K2K1K
Click to Share