Wastewater Monitoring Equipment for an Airport Group

 
CLEVELAND - April 25, 2022 - PRLog -- CAS DataLoggers recently provided the wastewater monitoring solution for a major airport support group whose fluid run-off threatened to endanger the aquatic ecosystem near the airports. They needed a device capable of monitoring fluid discharges into local waterways. The company routinely sprayed de-icing and anti-icing solutions onto their aircraft before they took off when conditions were conducive to ice formation as mandated by FAA guidelines. Between 100 and several thousand gallons of de-icing fluid were used per aircraft application. While a portion of the fluid stuck to the planes, approximately 75% to 80% of the treatment would flow into the surrounding environment as run-off.
The bases of many de-icing fluids contain propylene and ethylene glycol. While the de-icing solutions were being reformulated to be less toxic, there was still concern about the potential impacts of the fluids on the local environment.

Installation

CAS DataLoggers applications engineers determined a DT82 data logger equipped with an LTE cellular modem connected to an ultrasonic flow meter could immediately provide the airport remote online access to both current and historical data on discharge and flow volume. The DT82 system featured analog, digital and serial sensor interfaces, local data storage, smart power management, and batteries all incorporated into a single unit. The data recorder also intelligently controlled, powered the sensors, and provided the necessary calculation to derive both the flow rate and cumulative flow volume.  Data was transmitted from the data logger which was located near the wastewater discharge point to the company's server via the Microhard LTE Cube cellular modem. The wastewater flow was captured by an ultrasonic open channel flow meter which provided two 4-20 mA outputs, one for the flow velocity and one for the liquid level.

Usage

The dataTaker's many added capabilities helped staff to monitor the wastewater run-off more efficiently. For ease of use, airport staff could remotely configure the logger, and view both live and historic sensor data. The dEX2 software provided with the dataTaker provided an easy-to-use tool to configure the data logger, build dashboards, create graphs, and download stored data.

Benefits

The customer instantly benefitted from the installation of the DT82 wastewater monitoring system in several key ways. The data logger eliminated the complexity and cost of manually collecting and organizing the data from the airports' remote sensors. This complete solution was rapidly installed and implemented. Easy operation by personnel without relying on IT infrastructure became apparent as well. The advanced data display features allowed the airport group to more easily and efficiently monitor the run-off.

For more information on the dataTaker DT82, or other environmental monitoring applications, contact a CAS DataLogger Application Specialist at (800) 956-4437 or visit us at https://www.dataloggerinc.com.

Contact
CAS DataLoggers
Elizabethe Zala
***@dataloggerinc.com
End
Email:***@dataloggerinc.com Email Verified
Tags:Wastewater Monitoring
Industry:Industrial
Location:Cleveland - Ohio - United States
Subject:Reports
Account Email Address Verified     Account Phone Number Verified     Disclaimer     Report Abuse
CAS DataLoggers News
Trending
Most Viewed
Daily News



Like PRLog?
9K2K1K
Click to Share