Method of Reinforced Concrete Design

By: Global Associates
 
KOLKATA, India - Sept. 27, 2020 - PRLog -- A reinforced concrete structure is designed to fulfill the following parameters -

i)  Proper safety, with regard to stiffness and durability

iii)   Justifiable economy.

To design the RCC structures, the following design methods are mainly used :-

a)  The working stress method (WSM)

b)  The ultimate load method (ULM)

c)  The limit state method (LSM)

Working Stress Method (WSM)

This method is implemented on the basis of linear elastic theory or the classical elastic theory. This method ascertains tolerable safety by correctly constraining the stress in the materials (i.e. concrete and steel) caused by the projected working loads on the structures. The proposition of linear elastic behaviour legitimate as the specified allowable stresses are retained well under the ultimate strength of the material. The ratio of yield stress of the steel reinforcement or the cube strength of the concrete to the related allowable or working stress is normally known as factor of safety.

The WSM applies a factor of safety of about 3 relating to the cube strength of concrete and a factor of safety of about 1.8 relating to the yield strength of steel.

Ultimate load method (ULM)

This method is implemented on the basis of the ultimate strength of reinforced concrete since ultimate load is achieved by improving the service load with some factor known as load factor for providing a desired margin of safety. Therefore, the method is also called the load factor method or the ultimate strength method.

In the ULM, stress condition at the state of pending collapse of the structure is examined by applying the non-linear stress – strain curves of concrete and steel. The safely measure in the design is acquired by the application of proper load factor. The satisfactory strength performance at ultimate loads does not ensure the tolerable serviceability performance at normal service loads.

Limit state method (LSM)

Limit states stand for the satisfactory limits for the safety and serviceability requirements of the structure prior to failure takes place. The design of structures by this method will make sure that they will not attain limit states and will not become unsuitable for the use for which they are projected. The structures will not just fail or collapse by breaching (exceeding) the limit states. So, failure assumes that clearly defined limit states of structural usefulness has been surpassed.

Limit state are categorized in the following types :-

i)  Limit state of collapse

ii)  Limit state of serviceability.

~~~~~~~~~~~~~~~~~

Get some useful construction video tutorial (http://www.constructionnews.co.in/video.html)

Contact
Rajib Dey
***@gmail.com
End
Email:***@gmail.com
Tags:Civil Engineering
Industry:Construction
Location:Kolkata - West Bengal - India
Subject:Services
Account Phone Number Verified     Disclaimer     Report Abuse
mswindle PRs
Trending News
Most Viewed
Top Daily News



Like PRLog?
9K2K1K
Click to Share