Electrocon International to Exhibit CAPE 14 Protection Software at Texas A&M Relay Conference

Next generation computer-aided protection software for high voltage electrical transmission and distribution lines; Includes more than 6000 detailed relays, reclosers and fuses; Optional CAPE-TS Link™ integrates with Siemens PTI PSS®E transient
 
ANN ARBOR, Mich. - March 23, 2015 - PRLog -- Electrocon International, the full-service developer and marketer of CAPE software for protection system simulation and data management, will exhibit at the 68th Annual Conference for Protective Relay Engineers sponsored by Texas A&M University on March 30-April 2, 2015 in College Station, TX. Electrocon will demonstrate CAPE 14, the next generation version of Electrocon’s CAPE family of computer-aided protection software. CAPE offers extensive tools for detailed relay modeling that help engineers manage voluminous and complex network data, uncover potential problems, and examine alternative solutions. Supporting the system protection function within electric power utilities, CAPE is used by transmission, distribution and generation companies as well as electrical engineering firms in more than 50 countries on six continents worldwide.

“The 68th Annual Conference for Protective Relay Engineers will be the first public demonstration of CAPE 14, featuring new capabilities and enhancements most often requested by CAPE users worldwide,” remarked Paul F. McGuire, EE, MSEE, PE and President of Electrocon International.


http://www.electrocon.com/cape14.php

CAPE 14 includes a number of new features designed to enhance usability and improve engineering productivity, including:

* Automated time-distance diagrams with an option to store in database.

* Edit forms for adjusting existing double/triple/quadruple, ring, and breaker-and-a-half detailed bus structures.

* Point-to-point line structure for graphical representation of transmission lines and connection of point buses, bus ties, transformers, and shunts.

* On-line documentation with fast, simultaneous keyword-searching across all help.

* Support for NERC standards PRC-019-1 (coordination of Generator Voltage Regulator Controls with Unit Capabilities and Protection), PRC-023-2 Transmission Relay Loadability), PRC-025-1 (Generator Relay Loadability), and PRC-026-1 (Stable power Swing Relay Loadability).

* CAPE-TS Link™ option to integrate the detailed protection system model of CAPE with the time-domain model of the Siemens PTI PSS®E transient stability simulation.

* IPS-CAPE Bridge™ option to provide two-way data exchange between the IPS-RELEX™ protection system data management software and the CAPE protection system simulation environment.

* Special support for generator protection coordination tasks; display of generator capability curves; loss-of-field protection.

* Frequency relay models.

* Volts-per-Hertz relay models.

* 100+ new detailed relay models developed since CAPE 2010 bringing the total relays to more than 6000 detailed relay styles, reclosers and fuses.

* Modeling of generator and induction motor fault decay in Short Circuit, System Simulator, and Relay Checking.

* Support for modeling unbalanced three-phase transformers.

* Enhanced Shunt Capacitor Bank Performance macro.

* Quickscan fault studies.

* Quick protection system simulations in Short Circuit.

* CT saturation simulation in differential relays.

* Protection simulation speed enhancements.

* Many new hot key combinations.

* Sliding fault impedance feature.

CAPE Third-Party Interface Modules

CAPE offers optional connectivity with third-party software applications commonly used for planning and asset management. Two such modules include CAPE-TS Link and the IPS-CAPE Bridge™. In addition, the CAPE Neutral Interface (CAPE-NI) allows CAPE to share relay data with other asset management software.

Bridging the gap between Planning and Protection

A new optional module in CAPE 14 is the CAPE TS-Link module which integrates the detailed protection system model of CAPE with the time-domain model of the Siemens PTI PSS®E transient stability simulation. CAPE-TS Link was designed to aid in conducting compliance studies for the NERC PRC-026-1 standard for “Relay Performance During Stable Power Swings”. This unique simulation tool combines Electrocon’s premier stepped-event protection system simulation with time-domain transient stability programs.  It enables for the first time a reliable simulation of the bulk electric power system in a way that models the effect of protective relay operations on the dynamic behavior of the system.

The ability of the installed or planned protective devices to meet the critical clearing time criteria can now be demonstrated. CAPE’s library of detailed distance, overcurrent, voltage, and differential protective devices has been augmented with frequency and out-of-step relays to support unexcelled realism.

CAPE-TS Link is an option for CAPE 14 users with Siemens PTI PSS®E. Special introductory pricing is being offered to CAPE customers adding this module as a part of their upgrade to CAPE 14.

Protection System Data Management Connectivity

The IPS-CAPE Bridge provides two-way data exchange between the IPS-RELEX™ asset data management software and the CAPE protection system simulation environment. The Bridge manages the mapping of data common to both products in a way that preserves data integrity. Depending on the transfer the user requests, it can create new substations, LZOPs, relays, and relay settings in the destination database or simply update them if they already exist.

CAPE software is built for engineers responsible for protection of high voltage transmission systems and distribution systems within electric power utilities and includes:

* Detailed modeling capabilities based on a single open source database.

* Support for analysis and simulation to solve data management issues, uncover potential network and protective device problems, and evaluate alternatives.

* Support for networks of any size.

* Support for setting complex modern digital relays.

* Support for relay coordination functions and wide-area studies.

* Ability to integrate with conventional transient stability programs to allow the kind of evaluation of wide-area control needed to avoid cascading outages and blackouts.

CAPE handles networks of any size, large or small. CAPE users have systems ranging from under 100 buses to over 30,000 buses. Several have protection systems with 20,000 to 50,000 relays.

Simulating short circuits and showing the responses of protective devices

With CAPE, you use a mouse to click and drag elements on a one-line diagram, and to open breakers, apply faults, and simulate protective system responses. Conducting automated fault studies and wide area coordination reviews, developing incisive custom reports, and identifying fault locations, all become practical, efficient activities that add value to the organization.

CAPE users with active software maintenance agreements will automatically receive CAPE 14. Shipments of CAPE 14 will begin in the first quarter. For more information about CAPE, CAPE 14 or Electrocon services, visit us on the web at http://www.electrocon.com or call +1 734-761-8612 extension 202 or email eii@electrocon.com.

Contact
Bill Owens
***@electrocon.com
End
Electrocon International, Inc. PRs