Follow on Google News News By Tag Industry News News By Location Country(s) Industry News
Follow on Google News | Basic Principles Of Wind Tunnel Designs and Error Managements By Omkar WalambeA good quality wind tunnel will have a flow uniformity of 0.5-2% and turbulence intensity of 0.5-2%. It should provide temperature uniformity within 0.1-0.5oC at the inlet of the test section
By: Mass Flow Measurements Of Liquids Flowmeters There are two basic kinds of wind tunnels. One is the open type, which draws its air from the ambient and exits it back to the ambient. This kind of wind tunnel provides no temperature controls. The air follows the ambient temperature. The second type of wind tunnel is the closed loop wind tunnel, whose internal air circulates in a loop, separating it from outside ambient air. The temperature in a closed loop wind tunnel can be controlled using a combination of heaters and heat exchangers. Air temperatures can be varied from sub-ambient to over 100oC. Figure 1 shows a schematic of a closed loop wind tunnel. In general, closed loop wind tunnels are made with the following sections: 1- Test section 2- Settling chamber 3- Contraction area 4- Diffuser 5- Blower assembly 6- Heater/heat exchanger assembly Figure 1. Schematic of an ATS Closed Loop Wind Tunnel. A good quality wind tunnel will have a flow uniformity of 0.5-2% and turbulence intensity of 0.5-2%. It should provide temperature uniformity within 0.1-0.5oC at the inlet of the test section [1]. To achieve uniform, high quality flow in the test section, the settling chamber and the contraction area are used to smooth the flow. The role of the settling chamber, which is upstream of the contraction area, is to eliminate swirl and unsteadiness from the flow. The settling chamber includes a special honeycomb and a series of screens. As long as a flow’s yaw angles are not greater than about 10o, a honeycomb is the most efficient device for removing swirl and lateral velocity variations and to make the flow more parallel to the axial axis [2]. Large yaw angles will cause honeycomb cells to stall, which increases the pressure drop and causes non-uniformity in the flow. For large swirl angles, screen meshes should be placed before the honeycomb. For swirl angles of 40o, a screen with a loss factor of 1.45 will reduce yaw and swirl angles by a factor of 0.7. Several screens are needed upstream of the honeycomb to bring the swirl down to 10o. Using a honeycomb will also suppress the lateral components of turbulence. Complete turbulence annihilation can be achieved in a length of 5-10 cell diameters [2]. Honeycombs are also known to remove the small scale turbulence caused by the instability of the shear layer in front of them. This instability is proportional to the shear layer thickness, which implies a short honeycomb has a better ratio of suppressed turbulence to that generated. Screens break up large eddies into smaller ones which decay faster. They lower turbulence drastically when several screens are placed in a row. Screens also make flow more uniform by imposing a static pressure drop which is proportional to velocity squared. A screen with a pressure drop coefficient of 2 removes nearly all variations of longitudinal mean velocity. Low open area screens usually create instabilities. In general, screens should have openings larger than 57%, with wire diameters about 0.14 to 0.19 mm. Sufficient distance is needed between multiple screens to stabilize static pressure from perturbation. This distance is typically a percentage of the settling chamber diameter. The contraction area is perhaps the most important part of a wind tunnel’s design. Its main purpose is to make the flow more uniform. It also increases the flow at the test section, which allows flow conditioning devices to be at lower flow section with less pressure drop. Batchelor used the rapid distortion theory and estimated the variation in mean velocity and turbulence intensity [3] A considerable number of shapes have been investigated for contraction, including 2-D, 3-D and axisymmetric shapes with various side profiles. The shape of the contraction can be found using potential flow analysis. Consider the axisymmetric contraction shown in Figure 2 [4] Figure 2.-Schematic of an Axisymmetric Contraction [4]. The design of a wind tunnel is a lengthy process and, as shown above, it requires extensive knowledge and experience in both theory and construction. A novice might attempt to construct a tunnel, but considering the time spent, it might not be justified economically. Wind tunnel design also depends on economic and space constraints. Larger wind tunnels allow more space to have all the conditioning elements in place. A space-constrained wind tunnel must compromise some features at the cost of reduced flow quality, but can still be acceptable for practical engineering purposes. End
Account Email Address Account Phone Number Disclaimer Report Abuse
|
|