1. Latest News
  2. Submit Press Release
  1. PR Home
  2. Latest News
  3. Feeds
  4. Alerts
  5. Submit Free Press Release
  6. Journalist Account
  7. PRNewswire Distribution
Henniker Scientific Ltd. Logo

Henniker Scientific MAX-UF Series, Ultra-Fast Scanning Mass Spectrometers

The MAX Series quadrupole mass spectrometers from Henniker Scientific now feature dual, interchangeable analog and digital pulse ion counting pre-amplification stages that deliver individual data point acquisition at just 80 microseconds per sample.

 
 
Quadrupole-Mass-Filters
Quadrupole-Mass-Filters
PRLog - Dec. 6, 2011 - WARRINGTON, U.K. -- Extrel MAX-UF Series,
Ultra-Fast Scanning Mass Spectrometers

The Extrel MAX Series quadrupole mass spectrometers from http://www.henniker-scientific.com now feature dual, interchangeable analog and digital pulse ion counting pre-amplification stages that deliver individual data point acquisition at just 80 microseconds per sample.

Full range measurement over 10 decades is now possible with fractional mass unit detail at scan speeds in excess of 1000amu/sec, addressing a diverse range of fast transient studies in atomic and molecular physics and chemistry research.

Based around the industry leading 19mm triple filter quadrupole technology, each instrument is configurable with more than 25 ion source versions, choice of ion optics and energy filters for combined mass and energy analysis of positive and negative ions, and single or compound molecular beam inlet pressure reduction stages that span a wide pressure range from XHV to atmospheric pressure and above.

Mass range options extend to 16,000 amu for nano-cluster experiments, whereas high resolution versions are routinely capable of separating helium and deuterium. Partial pressures in the 10E-16mbar range can be measured with parts per billion abundance sensitivity and long term stability.

# # #

Henniker Scientific supply components, instruments & complete systems for a wide range of vacuum, thin film growth & deposition, UHV surface analysis, plasma treatment, plasma characterisation & gas analysis applications.

Photo:
http://www.prlog.org/11742280/1

--- End ---

Click to Share

Contact Email:
***@henniker-scientific.com Email Verified
Source:Henniker Scientific Ltd
Phone:+441925811254
Zip:WA3 6BU
City/Town:Warrington - Cheshire - United Kingdom
Industry:Research, Technology, Science
Tags:Mass Spectrometers, quadrupole, mass spectrometry
Shortcut:prlog.org/11742280
Disclaimer:   Issuers of the press releases are solely responsible for the content of their press releases. PRLog can't be held liable for the content posted by others.   Report Abuse

Latest Press Releases By “

More...

Trending News...



  1. SiteMap
  2. Privacy Policy
  3. Terms of Service
  4. Copyright Notice
  5. About
  6. Advertise
Like PRLog?
9K2K1K
Click to Share