Chroma introduces its new 63800 Series AC Electronic Loads designed for testing uninterruptible power supplies (UPS), Batteries, Off-Grid Inverters, AC sources and other power devices such as switches, circuit breakers, fuses and connectors.
-Power Rating : 1800W, 4500W
-Voltage Range : 50V - 350Vrms
-Current Range : Up to 45Arms
-Peak Current : Up to 135A
-Frequency Range : 45 to 440Hz, DC
-Parallel to 27KW single or three phase
-Power Factor Range : 0 to 1 lead or lag
-Constant & Rectified Load Modes
-Analog Voltage & Current Monitor
-Timing Measurement for Battery, UPS, Fuse & Breaker tests
Equipped with unique timing measurement functions, the 63800 Loads allow users to measure critical timing parameters such as battery discharge time, the trip time for fuse and breaker testing and UPS transfer time.
The Chroma 63800 Loads can simulate load conditions under high crest factor and varying power factors with real time compensation even when the voltage waveform is distorted. This special feature provides real world simulation capability and prevents overstressing thereby giving reliable and unbiased test results.
The 63800's state of the art designed uses DSP technology to simulate non-linear rectified loads in a unique RLC operation mode. This mode improves stability by detecting the impedance of the UUT and dynamically adjusting the load's control bandwidth to ensure system stability.